Equipment Design Data
Design Pressure(MPa): | -0.1~1.0Mpa | ||
Working pressure(Mpa): | -0.1~1.0Mpa | ||
Design Temperature(℃): | -19-200 | ||
Working Temperature(℃): | -19-180 | ||
High Voltage Test(KV): | 20 | ||
Enamel Thickness(mm): | 0.8-2.0 | ||
Application Medium: | It can withstand the corrosion of various concentrations of organic acids, inorganic acids, organic solvents and weak alkalis (except for hydrofluoric acid, fluoride ion-containing media, the phosphoric acid and strong alkali concentration is greater than 30%, and the temperature is greater than 180 degrees Celsius). | ||
Glass lined pipe main parameter list (Unit/mm)
DN | Pipe | D | D1 | D2 | L | H | t | Bolt | ||
dM | S | b | n | |||||||
50 | 57 | 3.5 | 140 | 110 | 90 | 110 | 16 | 3 | 14 | 4 |
70 | 76 | 4 | 160 | 130 | 110 | 125 | 16 | 3 | 14 | 4 |
80 | 89 | 4 | 185 | 150 | 128 | 145 | 18 | 3 | 18 | 4 |
100 | 108 | 4 | 205 | 170 | 148 | 155 | 18 | 3 | 18 | 4 |
125 | 133 | 4 | 235 | 200 | 178 | 185 | 20 | 3 | 18 | 8 |
150 | 159 | 4.5 | 260 | 225 | 202 | 195 | 20 | 3 | 18 | 8 |
200 | 219 | 6 | 315 | 280 | 258 | 200 | 22 | 3 | 18 | 8 |
250 | 273 | 8 | 370 | 335 | 312 | 250 | 24 | 3 | 18 | 12 |